Printer FriendlyEmail Article Link

Spirent TestCenter: How to determine frame loss location after an RFC-2544 test failure?

Answer
  • Make sure the RFC-2544 test includes saving details.
  • Using the saved results, filter on either the port or stream results to determine where the loss is occuring.
  • If the loss is occuring only on one Spirent TestCenter module, you could first try to reboot the module.
    • To reboot, go to Tools->Equipment Information, Modules tab
    • highlight the module and select reboot.
    • see FAQ10285 

Product : Spirent TestCenter,RFC 2544