Printer FriendlyEmail Article Link

Positioning Application: Can I simulate SBAS PRN's in the range 139- 158?

Environment/Versions
  • PosApp (SimGEN / SimREPLAYplus / SimREPLAY) v4-01 or later
    • SBAS scenario using EGNOS / WAAS / MSAS
Answer
  • The SBAS PRN range was extended to include PRNs 139 - 158 with PosApp v4-01
    • The full range being 120 - 158
  • Earlier versions of PosApp only support PRNs 120 - 138
     
  • Supported customer may upgrade to the latest PosApp version
    • Go to the Downloads tab on the CSC support website
    • Choose the category that matches your simulator model
       
  • Note that only SimGEN users can modify their scenarios to specify the required PRN
  • SimREPLAYplus / SimREPLAY users must request a 'special' scenario via the CSC support website specifying the PRNs they are interested to simulate

 

 


Product : SimREPLAYplus,SimREPLAY,SimGEN,PosApp,MSAS,EGNOS,WAAS,SBAS